CHLORIDE PHOTOMETER HANNA HI 96753

The HI 96753 is an auto diagnostic portable microprocessor meter. It has the advanced optical system based on a special Light Emitting Diode (LED) and a narrow band interference filter that allows most accurate and repeatable readings. All instruments are factory calibrated and the electronic and optical design minimizes the need of frequent calibration.

With the powerful CAL CHECK validation function, you are able to validate good performance of your instrument at any time. The validation procedure is extremely user friendly. Just use the exclusive HANNA ready-made, NIST traceable standards to verify the performance of the instrument and recalibrate if necessary.

All instruments are splash waterproof and the LED and filter units are protected from dust or dirt by a transparent cup. This makes the instruments fulfill field applications. Display messages aid the user in routine operation.

The meter uses an exclusive positive-locking system to ensure that the cuvette is in the same position every time it is placed into the measurement cell. It is designed to fit a cuvette with a larger neck making it easier to add both sample and reagents. The cuvette is made from special optical glass to obtain best results.

The HI 96753 meter measures the chloride (Cl-) content in water and wastewater samples in the 0.0 to 20.0 mg/L (ppm) range. The method is an adaptation of the mercury(II) thiocyanate method.

The reagents are in liquid form and are supplied in bottles. The amount of reagent is precisely dosed to ensure the maximum repeatability.

HI 96753 is supplied with (2) sample cuvettes with caps, 9V battery and instructions. CAL CHECKTM standards and reagents sold separately.



Technical data


Range:

0.0 to 20.0 mg/l


 

Resolution:

0.1 mg/l


 

Accuracy:

±0.5 mg/L ±6% of reading at 25°C


 

Light Source:

LED

 

 

Light Detector:

Silicon photocell with narrow band interference filter @ 466 nm

 

 

Power Supply:

1 x 9V battery

 

 

Auto-off:

After 10 minutes of non-use in measurement mode; after 1 hour of non-use in calibration mode; with last reading reminder.

 

 

Dimensions:

192 mm x 102 mm x 67 mm

 

 

Weight:

290 gr

 

 

Method:

Adaptation of the mercury(II) thiocyanate method.

Photo Code Title Quantity
CHLORIDE PHOTOMETER HANNA HI 96753 10.09.00.010 CHLORIDE PHOTOMETER HANNA HI 96753 Add this item to the basket
CHLORIDE PHOTOMETER HANNA HI 96753 10.09.00.011 CAL CHECK STANDARD CUVETTES FOR CHLORIDE PHOTOMETER HANNA HI 96753-11 Add this item to the basket
CHLORIDE PHOTOMETER HANNA HI 96753 10.09.00.012 REAGENTS FOR CHLORIDE PHOTOMETER HANNA HI 93753-01 / 100 TESTS Add this item to the basket